Aux AC Error Codes – How To Fix Them

Aux Group started development in 1986 and is an enterprise group that covers a wide range of industries in the market today. Taking on everything from electrical equipment to real estate, medical service, and investment they handle it all. Making them among the top 500 enterprises in China. What started as a small production house now offers appliances all over Asia and other parts of the world.

Aux AC may not be a common name on most continents, but is a reliable one for those who are familiar with its products. The company offers a number of great products that can be used in your home or in a commercial space. Offering you the ease and coverage you need with a lasting appliance.

When facing an error code we suggest you grab a pen and paper to note down the code rather than pressing various buttons on your Aux AC. This way you will not risk damaging your appliance any further and will be able to find out the exact issue using the common error code list for Aux AC error codes listed below. Once you nail down the issue you can easily call in a professional, or fix the issue yourself.

Codes List

Error CodesProblem
E1Plastic temp sensor is abnormal. The display precedence level: 2
E2Copper temp sensor is abnormal (outdoor). The display precedence level: 4
E3Copper temp sensor is abnormal (indoor). The display precedence level: 3
E4PG motor feedback is abnormal. The display precedence level: 1
E5Abnormality of outdoor unit
E6Over-current oprotection
E7External feedback failure
E8Overheat protection
E9Water pump failure
dFIndicates "dF"or defrosting indicator displays
L1Failure of coiled pipe sensor
L2Failure of room temperature sensor
L6Without feedback of internal fan motor

Remote Control

Aux Air Conditioner Remote Control
Aux Air Conditioner Remote Control

Wall Mounted AC Codes

AUX Air Conditioning Wall Mounted Error Codes
AUX Air Conditioning Wall Mounted Error Codes

Self-check information: Hint to defrosting

  • Self-check code of luminotron: Flicker 1 time/1s
  • Digital self-check code: Indicates “dF”or defrosting indicator displays

Self-check information: Hint to defense against cold wind

  • Self-check code of luminotron: Flicker 1 time/3s
  • Digital self-check code: Fan motor picture not running

Self-check information: Failure of room temperature sensor

  • Self-check code of luminotron: Flicker 2 times/4s (Flicker 2 times/8s)
  • Digital self-check code: E2/(L2)

Self-check information: Failure of coiled pipe sensor

  • Self-check code of luminotron: Flicker 3 times/5s (Flicker 1 time/8s)
  • Digital self-check code: E3/(L1)

Self-check information: Abnormality of outdoor unit

  • Self-check code of luminotron: Flicker 4 times/6s (luminating)
  • Digital self-check code: E4/(E5)

Self-check information: Without feedback of internal fan motor

  • Self-check code of luminotron: Flicker 5 times/7s (Flicker 6 times/8s)
  • Digital self-check code: E5/(L6)

Self-check information: Zero crossing signal without current

  • Self-check code of luminotron: Flicker 6 times/8s
  • Digital self-check code: E6

Self-check information: External feedback failure

  • Self-check code of luminotron: Flicker 7 times/9s
  • Digital self-check code: E7

Self-check information: Overheat protection

  • Self-check code of luminotron: Flicker 8 times/10s
  • Digital self-check code: E8

Self-check information: Water pump failure

  • Self-check code of luminotron: Flicker 9 times/11s
  • Digital self-check code: E9

Troubleshooting

Aux AC Error Codes and Troubleshooting
Aux AC Error Codes and Troubleshooting
TroubleCause
The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on.Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the signal is well received.
The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature.If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set.
The compressor works discontinuously at dehumidifying mode.The air-conditioner will automatically control the working of the compressor according to the inside temperature
The air-conditioner dose not work while the LED display is on.The TIMER is set with the air-conditioner,it will be in hold on condition. If the TIMER setting is cancelled, the air-conditioner will return to normal working condition.
The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down.The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.

Wiring Diagram

Wiring Diagram
Wiring Diagram

Manuals Pdf

Split Type AC Manual

Split Type Wall Mounted Air-Conditioner Owners Manual

Danny Reese
Latest posts by Danny Reese (see all)



*If you can't find the code you're looking for on our site, please let us know, and we'll update our database as soon as possible.

67 thoughts on “Aux AC Error Codes – How To Fix Them”

  1. Hi. I have an Aux 12000 btu. When I switch off the unit a CL error code appears on the display, flashing and makes a beeping sound 5 times before switching off.

    Reply
    • Did you find the reason? is problem solved. i cleaned the filter a few days ago and it was working fine for two days and now i am facing the same issue

      Reply

Leave a Comment