When the outdoor coil pipe TEMP sensor is out of order or removed, the air conditioner will set to defrost automatically in order to prevent it not working normally while the outdoor coil pipe TEMP sensor  is malfunction.

Fault F6: PG motor faults

Fault F7: Indoor TEMP sensor faults

Fault F8: Indoor coil pipe TEMP sensor faults




Fault F9: Outdoor coil pipe TEMP sensor faults

Galanz Air Conditioner Error Codes
Galanz Air Conditioner Error Codes

Wall Mounted Type

Indoor unit display and solve methods of protector stop ingredients in indoor unit and outdoor unit

Error CodesTrouble
F1Heat overloading protector
F2Cool freeze protector
F3Instantaneous power cut
F4direct current fan motor no feedback
1Fcool overloading protector
2Fexhaust overheating protector
3Fover or not enough pressure protector
4Fover-current protector
5FIPM protector
6Fdefrost state
7Fdirect current compressor drive exceptional
8Fdirect current compressor cannt start
Galanz Air Conditioner Remote Control
Galanz Air Conditioner Remote Control

Trouble Solve Methods

E1: The trouble of indoor unit room temperature sensor.

E2: The trouble of unit pipe temperature sensor. indoor

E3: The trouble of PG motor

E5: The trouble of bad communication of indoor unit and outdoor unit.

E6: The EEPRO of indoor unit error

1E: The trouble of outdoor unit pipe temperature sensor

3E: The trouble of exhaust sensor




4E: The EEPRO of indoor unit error

8E: The trouble of PFC.

Troubleshooting

Operation of air conditioner: Fan speed setting is not allowed in AUTO or DRY mode

Explanation: The speed of the indoor fan is set to low in DRY mode. Fan speed of 3 steps is selected automatically in AUTO mode

Operation of air conditioner: Compressor stops operation intermittently in DRY mode

Explanation: Compressor operation is automatically controlled in DRY mode depending on the room temperature and humidity

Operation of air conditioner: Compressor of the outdoor unit is operating although it is turned off in HEAT mode

Explanation: When the unit is turned off while de-ice is activated, the compressor continues operation for up to 10 minutes (maximum) until the deice is completed

Operation of air conditioner: Timer indicator lamp lights up and the air conditioner does not operate

Explanation: Timer is being activated and the unit is in ready mode. The unit operates normally if the timer operation is cancelled

Operation of air conditioner: The compressor and indoor fan stop intermittently in HEAT mode

Explanation: The compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protect the compressor from overheated air in HEAT mode

Operation of air conditioner: Indoor fan and outdoor fan stop intermittently in HEAT mode

Explanation: The compressor operates in a reverse cycle to remove exterior ice in HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heat operation

Operation of air conditioner: The compressor stops intermittently in COOL mode or DRY mode, and fan speed of the indoor unit decreases



Explanation: The compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozen depending on the inside/outside air temperature.