Sanyo Electric Co., Ltd. is a Japanese electronics company that was a former member of the Fortune 500 Global. With headquarters in Moriguchi, Osaka prefecture, Japan the company had more than 230 subsidiaries and affiliates. Founded by Toshio lue back in 1947 the company has made a great mark on the world. However, things took a turn when in 2009 Panasonic purchased 50.2% stocks of Sanyo making it a subsidiary of Panasonic. In just two years Panasonic purchased 100% stocks making it the sole owner.

Sanyo started its journey with Japan’s first plastic radio and pulsator-type washing machine launched in 1954. It was not until 1970 that Sanyo introduced audio equipment, car stereos, and other consumer electronics.

Sanyo might be a high-ranking company, but from time to time customers have complained about system errors. Fortunately, most of these errors can be fixed on your own. So rather than ignoring the error codes, your appliance is showing its time to note down the Sanyo air conditioner error code and get to the bottom of the problem. To help you out we have listed down the most common error codes of Sanyo air conditioners.

Since the indications cover various units, the corresponding parts listed below may not be present in some models.

Codes List

Error CodeMeaning
S01Room temperature sensor failure
S02Indoor heat exchanger sensor failure
S03Humidity sensor failure
S04Compressor temperature sensor failure
S05Outdoor heat exchanger sensor failure
S06Outdoor air temperature sensor failure
S07Outdoor electrical current detection faillure
E01lndoor/outdoor communications failure
E02HIC circuit failure
E03Outdoor unit external ROM (OTP data) failure
E04Peak current cut Off
E05PAM circuit failure
E06Compressor discharge overheat prevention activated
E07Indoor fan operating failure
E084-way valve switching failure
E09No-reirigerant protection
E10DC compressor drive circuit failure
E11Outdoor fan operating failure
E12Outdoor system communications failure
E13Freeze-prevention operation activated

Possible Cause of Malfunction

Sanyo AC Fault Codes
Sanyo AC Fault Codes
Error CodesMeaning
E01serial comms error, mis-setting, RC is detecting error signal from IU, outdoor system address, indoor system address.
E02serial comms error, mis-setting, RC is detecting error signal from IU, error in transmitting serial comm signal
E03IU is detecting error signal from remote controller (and system controller)
E04IU is detecting error signalled from OU, error in receiving serial comms signal
E05IU is detecting error signalled from OU, error in transmitting serial comms signal
E06OU is detecting error signalled from IU, error in receiving serial comms signal (inc unit qty verification failure)
E07OU is detecting error signalled from IU, error in transmitting serial comms signal
E08improper setting of IU or RC,IU address is duplicated
E09improper setting of IU or RC, remote controller setting is duplicated
E10IU is detecting error signalled from signal option, error in transmitting serial comms signal
E11IU is detecting error signalled from signal option, error in receiving comms signal
E12IU is detecting error signalled from signal option, because auto address setting is in process in a different system.
E14setting error, main unit duplication in simultaneous-operation multi control (detected by outdoor unit)
E15automatic address setting failed, IU capacity too low
E16automatic address setting failed, IU capacity too high
E17an IU detected trouble in the signal from another IU, error in transmitting serial comms signal
E18an IU detected trouble in the signal from another IU, error in receiving serial comms signal
E20automatic address setting failed, no signal received from another IU
E24Auto address error, Main OU is detecting error signal from sub OU
E25Auto address error, of OU address setting
E26Auto address error, the number of connected main and sub OU do not correspond to the number set at the main OU PCB
E29auto address error, sub OU in receiving serial comm signal from main OU
F01thermistor fault, indoor coil temp. sensor (E1)
F02thermistor fault, indoor coil temp. sensor (E2)
F03thermistor fault, indoor coil temp. sensor (E3)
F04Outdoor thermistor open circuit, discharge TD1
F05Outdoor thermistor open circuit, discharge TD2
F06Outdoor thermistor open circuit, heat exchanger temperature C1
F07Outdoor thermistor open circuit, heat exchanger temperature C2
F08thermistor fault, outdoor air temp. sensor (air temp)
F10thermistor fault, indoor suction air (room) temp sensor (TA)
F11thermistor fault, indoor discharge air temp. sensor (BL)
F12Outdoor thermistor open circuit, intake temperature TS
F16thermistor fault, outdoor high pressure sensor
F17thermistor fault, outdoor unit low pressure sensor
F22thermistor fault, outdoor unit compressor 3 (constant speed) discharge temp sensor
F23thermistor fault, outdoor No. 2 coil gas temp (EXG2)
F24thermistor fault, outdoor No. 2 coil liquid temp. sensor (EXL2)
F25thermistor fault, outdoor unit heat exchanger 3 gas temp. sensor
F26thermistor fault, outdoor unit heat exchanger 3 liquid temp. sensor
F29indoor EEPROM error
F31outdoor EEPROM error
H01AC1 compressor protection, overload current was detected
H02AC1 compressor protection, lock current was detected
H03AC1 compressor protection, no current was detected when the compressor was ON (CT1 circuit failure)
H05the compressor discharge sensor has become disconnected (detected only for the AC1 compressor)
H06low pressure switch activated on AC1, AC2 compressor
H07protective device for compressor is activated, low oil level
H08protective device for compressor is activated, compressor no. 1 oil sensor fault (disconnection, etc)
H11AC2 compressor protection, overload current was detected
H12AC2 compressor protection, lock current was detected
H13AC2 compressor protection, no current was detected when the compressor was ON (CT2 circuit failure)
H15the AC2 compressor discharge sensor has become disconnected
H21outdoor protective device, overload current detected on compressor 3 (constant speed)
H22outdoor protective device, lock current detected on compressor 3 (constant speed)
H23outdoor protective device, no current detected when compressor 3 (constant speed) was on
H25outdoor protective device, discharge temp. sensor trouble, Compressor 3 (constant speed)
H27protective device for compressor is activated, compressor no. 2 oil sensor fault (disconnection, etc)
H28connection failure of oil detection sensor, compressor no 3 (contestant speed)
H31outdoor unit protection IPM trip (IPM current or temperature) HIC Alarm trouble
L02mis-setting error, IU/OU type mismatch
L03mis-setting error, main unit duplication in group control (detected by IU)
L04mis-setting error, OU address duplication (system address)
L05improper setting, there are 2 or more IU RC which have operation mode priority in refrigeration circuit.
L06improper setting, there are 2 or more IU RC which have operation mode priority in refrigeration circuit.
L07mis-setting error, group wiring connected for independent IU
L08mis-setting error, IU address not set or group not set
L09mis-setting error, IU capacity not set
L10mis-setting error, OU capacity not set or setting error
L11mis-setting error, miswiring in group control wiring
L13mis-setting error, IU type setting error
L17mis-match connection of outdoor units which have a different kind of refrigerant
L184-way valve operation failure
LCMalfunction of transmission between control and inverter PCB.
P01indoor fan protective thermostat
P02the AC compressor or AC1, AC2 compressor internal protection thermostat was activated: or low voltage was detected
P03discharge temperature trouble on outdoor
P04High pressure sensor operation on AC, AC1 or AC2 compressor
P05open phase detected, AC power trouble
P09ceiling panel connection failure
P10indoor float switch
P12indoor fan overload (check for packaging on new cass install)
P16compressor running failure resulting from missing phase in the compressor wiring etc
P17incorrect discharge temperature (comp no 2)
P22outdoor unit fan (missing phase in the HALL IC or other problem) causing the fan to lock
P26overcurrent at time of compressor runs more than 80hz (DCCT secondary current or ACCT primary current at a time other than when IPM has tripped
P29inverter for compressor is unusual (DC compressor does not operate)
P31a flexible control error occurred
Sanyo AC Remote Control Unit (Display)
Sanyo AC Remote Control Unit (Display)

Troubleshooting

If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or service center.

TroublePossible Cause
Air conditioner does not run at all.1. Power failure. Restore power. 2. Leakage circuit breaker tripped. Contact service center. 3. Line voltage is too low. Consult your electrician or dealer. 4. Batteries in remote control unit have run down. Replace batteries.
Operation lamp blinks and air conditioner does not operate.Trouble in system. Contact service center.
Compressor runs but soon stops.Obstruction in front of condenser coil. Remove obstruction.
Poor cooling (or heating) performance.1. Dirty or clogged air filter. Clean air filter to improve airflow. 2. Heat source or many people in room. Eliminate heat source if possible.
Clicking sound is heard from the air conditioner.In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear.
Operation lamp lights but outdoor unit will not run.The use of cellular phones near the air conditioner may cause disturbance to its normal operation. 1. Turn off the power then restart the air conditioner after a while. 2. Consult your dealer.