UnionAire is a mother company that has taken over a number of companies in its home appliance distribution and manufacturing world. What was once a dream is now one of the biggest companies in the world. Founded back in 1995 the company had a clear vision that they saw through every step of the way. Investing in the best choices allowed them a chance to bring consumers appliances that are durable and reliable.
Currently, the company offers a wide range of appliances all around the world, offering every consumer a chance to enjoy some of the best appliances the world has to offer. That is produced with the help of other diversified companies that are owned by the same group.
There is a time in your life when the most reliable appliance you have starts to show an error. While it might be a dark day, fortunately for you there is a simple solution for most error codes. To help you out we have accumulated a complete list of the Unionaire air conditioner error codes. Offering you a chance to find out exactly what is wrong with your appliance, so you can finally make a decision. Rather than fighting with the appliance, or spending endless money on the repair, we suggest you first find the problem and then look for a solution.
Most Common Codes
Error Codes | Problem |
---|---|
E1 | Room Sensor Missing. Flashing Led: Power |
E2 | Indoor Sensor Missing. Flashing Led: Power+Sleep |
E3 | Outdoor Sensor Missing. Flashing Led: Power |
E4 | Compressor Overload. Flashing Led: Power+Cool |
E5 | Insufficient cooling or heating ''due to'' ; Incorrect voltage, Gas leakage, Indoor sensor. Flashing Led: Power+Cool |
P1 | Over voltage or too low voltage protection |
P2 | emperature protection of compressor top. |
Remote Control Meaning
How to Fix E1?
Room Sensor: this code means that the circuit board is not receiving a signal from the sensing bulb mounted in front of the evaporator coil. Diagnosis: visually inspect and/or use an ohmmeter to check the following:
- Sensor has come unplugged from the PC board. OR
- Sensor has failed and must be replaced. OR.
- Sensor wire has shorted or opened necessitating the repair of the wire.
How to Fix E2?
Indoor Sensor: this code means that the PC board is not receiving a signal from the copper sensing bulb mounted to the side of the evaporator coil. Diagnosis: visually inspect and/or use an ohmmeter to check the following:
- Sensor has come unplugged from the PC board. OR.
- Sensor has failed and must be replaced. OR.
- Sensor wire has shorted or opended necessitating the repair of the wire.
How to Fix E3?
Outdoor Sensor: (Heat Pump Only) this code means that the PC board is not receiving a signal from the copper sensing bulb mounted to the copper tubing near the condenser coil. Diagnosis: visually inspect and/or use an ohmmeter to check the following:
- Sensor has come unplugged from the PC board. OR.
- Sensor has failed and must be replaced. OR.
- Sensor wire has shorted or opened necessitating the repair of the wire, since this wire runs through one or more walls, the likelihood of the wire being cut is probable.
How to Fix E4?
Compressor Overload: this code means that one of the safety overloads on the compressor has activated. Diagnosis: the compressor has both an electrical and a temperature overload device built into it. The thermal overload will trip if the gas temperature reaches 154.4° Fahrenheit. This error can be reset by turning the unit off and on. Try one of the following solutions:
- High ambient temperature, with a low ambient kit installed, Unionaire systems will function up to 122° Fahrenheit.
- Blockage in the refrigerant circle, make sure both service valves are fully open, a high pressure on the liquid side, over 350 psig, and a low suction side, under 40 psig, indicates a blocked cap tube. If a blockage is diagnosed, the system must be evacuated, blown back and cleared. It is recommended that a filter/dryer be installed in the vapor line before pumping down and recharging.
- Condenser fan not working, if the compressor runs, but the fan does not, the motor or its capacitor may have failed. Repair or replace as necessary.
- Compressor problem, if the compressor has developed internal faults, it could simply be starving for oil. Examine the installation of the unit to insure that the refrigerant lineset has been trapped properly to facilitate oil return. Any other internal problem with the compressor will mean replacement is necessary.
- Compressor wiring, if the compressor and/or its capacitor have been wired incorrectly, the compressor could overload. Rewire as necessary.
How to Fix E5?
Low refrigerant charge: this code means that the refrigerant charge within the system is not adequate to run it without frosting the coils. diagnosis: the refrigerant charge must be brought to within specified parameters. Possible causes of a low charge could include the following:
- The factory charge in Unionaire condensers is enough for the whole system with 13 feet of lineset, but may have been short, see the temperature/pressure chart to charge it within specifications.
- Leaking, the system may have a leak which must be located with a refigerant detector, or by a sop test, most leaks can be braised up, however, if a component such as a 4 way valve has developed a leak, it will need replacing.
- Lineset lengthened and/or increased in diameter. A lineset longer than 13 feet, or larger in diameter than that with which it came will require that additional refrigerant be added.
Troubleshooting
Problem | Solution |
---|---|
The unit can not be restalted just after shut down. ( RUN lamp is illuminating ) | Restart is stopped for 3 minutes afler shut down to protect the unit. Thlee-minute protection timer incorporated in the miomoomputer ectuates automatically. Except that power is connected , this fundion does not actuate. |
Air is not blown out at starting of heating operation. | Air blow is stopped to prevent blowing out of cold air until the indoor heat exchanger is wenned. ( 2 to 5 min ) ( HOT KEEP) |
Air is not blown out for 6 to 12 min, at heating operation. | When outdoor temperature is low and humidity is high, the unit sometimes performs defrosting automatically. Please wait. During defrosting, water or steam are raising from the outdoor unit. |
Air is not blown out at DRY operation. | Indoor fan is sometimes stopped to prevent vapor of dehumidified moisture and save energy. |
Mist is blown out at COOL operation. | This phenomenon sometimes occurs when the temperature and humidity of the room are very high , but it will disappear with the lowering of the temperature and humidity. |
Odor is sent out. | Air blown out during operation may smell. This is the smell of tobacco or cosmetics sticked to the unit. |
Noise is heard cracking sound. | This is caused by the refrigerant that is circulating inside the unit. |
Operation can not be restarted even if the power is recovered. | The memory circuit of the miclocompumr is cleared. Operate the remote controller again to restart the operation. |
Remote control signals are not received. | Remote control signals may not be leceived when signal receiver on the air conditioner body is exposed to direct sunlight or strong lighting . In that case , interrupt the sunlight or damen the lighting. |
Manual Pdf
Unionaire Air Conditioner Manual PDF
- Aux AC Error Codes – How To Fix Them - November 15, 2024
- LG VRF Error Codes List – Multi V - November 15, 2024
- Black and Decker AC Error Codes List and Fixes - November 1, 2024
Respected sir in 2 ton unionaire wall a.c. e1 error have shown…I change room sensor again it shows room sensor problem and at last I change pcb from another unionaire machine and it shows again e1…..what is the actual problem Sir…reply me soon sir
air conditioner spewed smelly realized in the other that something is burning and then appeared on the screen error number79, what the meaning of this error and how to fix it,thank u
how do i solve the problems of an union aire air conditon eror E5?
Window type 1200 BTU error code E3,
I am keeping press power botton to get back work normal again, let me know what i need to change, fix or add to avoid this error
How I can solve the problem E5 in unionair 24000 BTU