The Most Common Error Codes Of Actron AC

ActronAir is an Australian company that was established back in 1984. Since its inception, the company has been working on manufacturing and distributing world-class air conditioning technology along with other appliances that make your home and office a smart and efficient working system. Offering you a wide range of reliable appliances ActronAir caters to local markets in the best way possible.

Being an Australian original it understands the heat, humidity, snow, and rain weather conditions – making them an expert on the matter. This way they are able to offer customers an appliance that will last for years while offering them exceptional workings.

Regardless of how high a company is ranked, or how well the appliance is reviewed, you are at the risk of an error. An error is not here to tell you it’s time to switch out your appliance, it’s a direct signal from the device – one that tells the owner something is wrong with the system that needs to be fixed. So rather than ignoring the error codes, your appliance is showing its time to note down the Actron ac error code and troubleshoot to get to the bottom of the problem. To help you out we have listed down the most common error codes.

Most Common Codes

Error CodesProblem
E1Outdoor coil sensor open or closed circuit
E2Fault indoor coil out sensor
E3Fault room sensor
E4Fault indoor coil sensor
E5Communication error between outdoor and indoor
E6Fault Discharge temperature
E7Fault outdoor coil sensor
E8Fault outdoor discharge sensor
E9High or Low Pressure/Phase error

E3: System has detected less than 2 sensor ( Ultima requires at least 2 sensors in circuit) or, a remote sensor is short circuit.

E5: No Communication. The system is constantly relaying information back and forth. This indicates the communication is not happening. Contact your installer to check your wiring and cable’s integrity

M Series (AM24 and AM7) Controller Error Fault Codes
M Series (AM24 and AM7) Controller Error Fault Codes
C Series (C7-1) Controller Error Fault Codes
C Series (C7-1) Controller Error Fault Codes
Actron air fault codes
Actron air fault codes
Actron AC ESP Unit Error Fault Codes
Actron AC ESP Unit Error Fault Codes

AC Remote Control Display

Actron AC Remote Control Display
Actron AC Remote Control Display

AC System Control Alarm Mix

Actron AC System Control Alarm Mix
Actron AC System Control Alarm Mix

Troubleshooting

Conditions: The system does not start.

Remedy:

  • Check that 5 minutes has passed from the time you turned the system on as there are in-built safety timers.
  • Check thermostat settings are correct.
  • Check thermostat set point is low enough for cooling or high enough for heating.
  • Check the Master Controller is set to the correct mode for COOL/AUTO/HEAT.

Conditions: Air does not flow.

Remedy:

  • Check if the unit is set in the correct mode COOL/AUTO/HEAT.
  • Check your zone control is turned on. If using sensor ensure your zone is on at the master.
  • During defrost cycle of the outdoor unit in heating mode, the indoor fan will not operate. Defrost cycle is indicated when the heat LED on the master control is flashing.

Conditions: OFF is displayed on my zone control and I can not turn it on.

Remedy: This means the Master Controller is turned off. First turn on your air conditioner at the master control. You will now be able to turn on your zone control.

Frequently Asked Questions

1- I can not adjust my set point on my zone controller any more than 2 degrees higher or lower than the master controller.

-2 degrees is the the default setting for master temperature offset. ActronAir recommend this 2 degree offset to optimise temperature control and maximize energy efficiency. Moving this settings outside +/-2 degrees will result in temperature inaccuracy

2- Cooling and Heating seems to take a long time to achieve temperature in ESP fan mode. Am I using the correct settings?

-ESP fan mode really comes into it’s own when minimal zones are used. For quicker and more responsive Cooling and Heating when using more than minimal zones, select High or Cont High fan speed on the master control. This will boost heating and cooling and is best optimized when you want to condition more than the minimal zone set up.

3- Cooling and Heating is not sufficient in my zone.

-Air balancing is essential part of system commissioning in Ultima system. The duct design may be prohibiting the correct amount of airflow reaching your area. Please contact your installer to ensure air balancing has been carried out.

4– There is substantial air noise coming from my outlet.

-If the outlet gets too noisy when the unit or zone is first turned on, the system maybe over supplying airflow to your area. Ensure ESP fan mode is used when using minimal zones.Please contact your installer to ensure air balancing has been carried out.

5- There are dashes across my control display

-Make sure you have not had a power cut out. If this is still present on the display after 20 seconds, please contact your installer. Incorrect wiring or a broken circuit could also cause these symptoms

Manual Pdf

Actron AC Manual Pdf

Actron AC Troubleshooting – Error Fault Codes PDF

Reference: www.actronair.com.au

Danny Reese
Latest posts by Danny Reese (see all)



*If you can't find the code you're looking for on our site, please let us know, and we'll update our database as soon as possible.

15 thoughts on “The Most Common Error Codes Of Actron AC”

    • We have an E-C error code on our Pioneer ducted air conditioning unit, model numbe BM2-24H-4Z/GP.
      What does this mean?

      Reply
  1. We had a power surge during a storm. Wall controller said “error 9”. I have reset it as per instructions. We have 5 zones, 3 upstairs & 2 downstairs but only 2 zones upstairs are working. What could be wrong please?

    Reply
  2. I have an Actron 18.6kw ESP plus Platinum model and I am getting an Error code E15 and the RUN is flashing.

    Does anyone know what this means?

    The air conditioner is not cooling nor heating

    Reply
    • Bill we have just got the same error message. Doesn’t seem to be in any of the manuals. Did you ever find out what was wrong? I managed to get the “run” to disappear by resetting it, but the E 15 message just comes back unfortunately.

      Reply

Leave a Comment