Chicago was founded in 1994 but has quickly gained a great deal of attraction and attention from the world. Known as Guangdong Chigo Air Conditioning Co., Ltd, the 26-year-old corporation has seen great highs in terms of manufacturing and sales. With headquarters in Nanhai District, Foshan City they are regarded as the key manufacturers of air conditioners, refrigerators, washing machines, and other household appliances.
In only 2 decades the business was able to double its capacity, and offer more than 10 million air conditioner sets that are available in more than 200 countries around the world. Making sure you get access to the best appliance the company has to offer no matter where you are located.
There is a time in your life when the most reliable appliance you have starts to show an error. While it might be a dark day, fortunately for you there is a simple solution for most error codes. To help you out we have accumulated a complete list of the Chigo air conditioner error codes. Offering you a chance to find out exactly what is wrong with your appliance, so you can finally make a decision. Rather than fighting with the appliance, or spending endless money on the repair, we suggest you first find the problem and then look for a solution.
Codes List
Error Codes | Solution |
---|---|
E1 | Condenser temperature aensor fault |
E2 | Room temp. sensor fault |
E3 | Coil temp. sensor fault |
E4 | Outdoor unit abnormal |
E5 | No feedback signal of indoor fan |
E6 | No over zero signal |
E7 | Outdoor feedback fault |
E8 | Frost protection/over heat protection |
F1 | Communication fault |
F2 | Ambient temp. sensor fault |
F3 | Coil pipe temp. sensor of indoor unit fault |
F4 | Fan motor of indoor |
F5 | Module of outdoor unit fault |
F6 | Ambient temp. sensor of outdoor fault |
F7 | Coil pipe temp. sensor of outdoor unit fault |
F8 | Suction temp. sensor of compressor fault |
F9 | Discharge temp. sensor of compressor fault |
FA | Inductor of current or voltage fault |
FC | Compressor drive fault |
FD | Phase lacking or phase sequence fault |
FE | Gas return sensor fault |
FF | Other fault |
P1 | Temp. of evaporator protection |
P2 | Overheat, over current protection of inverter module |
P3 | Over current protection |
P4 | Discharge temp. of compressor protection |
P5 | Over heat of compressor top protection |
P6 | Suction temp. of compressor protection |
P7 | Low or high voltage protection |
P8 | Low presser of gas return protection |
P9 | High pressure of discharge protection |
PA | High temp. of condenser protection |
PC | High temp. of outdoor ambient protection |
PF | Other protection |
DF | Defrost indication |
Wall Split AC Series
Code: DF
Failure: Defrost indication
The reason of fault and solution: Normal, the defrost state is removed, it will return to normal condition automatically
Code: E2
Failure: Room temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of the sensor is normal (the resistance is 5КΩ in the normal temperature 25 ) ℃ , when it is abnormal the sensor should be replaced.
- Check whether there is short circuit or open circuit in the wire of the sensor, and whether the plug is connected well, whether there is welding off or rosin joint on the electric control board, if there is any, it should be repaired.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: E3
Failure: Coil temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of the sensor is normal (the resistance is 5КΩ in the normal temperature 25 ) ℃ , when it is abnormal the sensor should be replaced.
- Check whether there is short circuit or open circuit in the wire of the sensor, and whether the plug is connected well, whether there is welding off or rosin joint on the electric control board, if there is any, it should be repaired.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: E4
Failure: Outdoor unit abnormal
The reason of fault and solution:
- Check whether the winding resistance and operation current of the compressor are normal.
- Check whether the high and low pressure is normal when the unit is running.
- Check (whether the coil pipe sensor is normal) whether the contact of the inserter on the circuit board is well, the coil pipe temperature sensor is fixed, the evaporation of the indoor unit is well, the key is to check the evaporator temperature detected by the coil pipe temperature sensor has reached the cooling or heating temperature.
- Check whether the surface of the condenser is too dirty, it should be cleaned when it is too dirty.
- Check whether the capacitance of the outdoor motor and the fan is damaged, it should be replaced when
Code: E5
Failure: No feedback signal of indoor fan
The reason of fault and solution:
- Check whether two sets of plugs on the outlet end of the motor have loosed from the socket of the electric control board, insert it firmly when loosing.
- Check whether the indoor motor has damaged, the motor should be replaced when it is damaged
- Check whether the controllable silicon and other components on the electric control board have damaged, replace the controllable silicon or electric control board when they are damaged.
Code: E6
Failure: No over zero signal
The reason of fault and solution:
- Firstly check whether the indoor fan is normal.
- Check whether the signal outputting from the integrated chip of the electric control board is normal, the electric control board should be replaced when the signal is abnormal.
Code: E7
Failure: Outdoor feedback fault
The reason of fault and solution:
- Check whether the winding resistance and operation current of the compressor are normal
- Check whether the high and low pressure is normal when the unit is running.
- Check whether the indoor and outdoor wiring is right; when it is wrong, connect them again according to the circuit diagram
- Check whether the contact of the inserter on the circuit board and the connection are well, otherwise repair.
- Check whether the signal feedback wire is disconnected, replace or connect the feedback signal wire.
- Check whether the supply power is phase-lacking or phase opposition.
- Check whether the AC electromagnetic contactor is well.
Code: E8
Failure: Frost protection/over heat protection
The reason of fault and solution:
- Check whether the filter of the indoor unit is dirty or blocked, and clean if it is dirty.
- Check whether the indoor fan is running normally, and replace the motor if it is abnormal.
- Check whether indoor pipe temperature sensor is normal, and replace the sensor if it is abnormal.
- Check whether the system pressure is normal, if abnormal, should check whether there is leakage, and fill the refrigerant again.
Floor Standing AC Series
Code: E2
Failure: Room temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of the sensor is normal (the resistance is 5КΩ in the normal temperature 25 ) ℃ , when it is abnormal the sensor should be replaced.
- Check whether there is short circuit or open circuit in the wire of the sensor, and whether the plug is connected well, whether there is welding off or rosin joint on the electric control board, if there is any, it should be repaired.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: E3
Failure: Coil temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of the sensor is normal (the resistance is 5КΩ in the normal temperature 25 ) ℃ , when it is abnormal the sensor should be replaced.
- Check whether there is short circuit or open circuit in the wire of the sensor, and whether the plug is connected well, whether there is welding off or rosin joint on the electric control board, if there is any, it should be repaired.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: E4
Failure: Outdoor unit abnormal
The reason of fault and solution:
- Check whether the winding resistance and operation current of the compressor are normal.
- Check whether the high and low pressure is normal when the unit is running.
- Check (whether the coil pipe sensor is normal) whether the contact of the inserter on the circuit board is well, the coil pipe temperature sensor is fixed, the evaporation of the indoor unit is well, the key is to check the evaporator temperature detected by the coil pipe temperature sensor has reached the cooling or heating temperature.
- Check whether the surface of the condenser is too dirty, it should be cleaned when it is too dirty.
- Check whether the capacitance of the outdoor motor and the fan is damaged, it should be replaced when it is damaged.
- If the above items are normal, the electric control board should be replaced.
Code: E7
Failure: Outdoor feedback fault
The reason of fault and solution:
- Check whether the winding resistance and operation current of the compressor are normal
- Check whether the high and low pressure is normal when the unit is running
- Check whether the indoor and outdoor wiring is right; when it is wrong, connect them again according to the circuit diagram
- Check whether the contact of the inserter on the circuit board and the connection are well, otherwise repair.
- Check whether the signal feedback wire is disconnected, replace or connect the feedback signal wire.
- Check whether the supply power is phase-lacking or phase opposition.
- Check whether the AC electromagnetic contactor is well.
Code: E8
Failure: Frost protection /over heat protection
The reason of fault and solution:
- Check whether the filter of the indoor unit is dirty or blocked, and clean if it is dirty.
- Check whether the indoor fan is running normally, and replace the motor if it is abnormal.
- Check whether indoor pipe temperature sensor is normal, and replace the sensor if it is abnormal.
- Check whether the system pressure is normal, if abnormal, should check whether there is leakage, and fill the refrigerant again.
Portable AC Codes
Code: E2
Failure: Room temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of the sensor is normal (the resistance is 5КΩ in the normal temperature 25 ) ℃ , when it is abnormal the sensor should be replaced.
- Check whether there is short circuit or open circuit in the wire of the sensor, and whether the plug is connected well, whether there is welding off or rosin joint on the electric control board, if there is any, it should be repaired.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: E3
Failure: Coil temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of the sensor is normal (the resistance is 5КΩ in the normal temperature 25 ) ℃ , when it is abnormal the sensor should be replaced.
- Check whether there is short circuit or open circuit in the wire of the sensor, and whether the plug is connected well, whether there is welding off or rosin joint on the electric control board, if there is any, it should be repaired.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: E4
Failure: Abnormal protection
The reason of fault and solution:
- Check whether the operation current and power of the unit is abnormal.
- Check whether the speed and wind quantity of the fan is normal, otherwise replace the outdoor fan or capacitance
- Check whether the surface of the condenser is too dirty, and it should be cleaned when it is too dirty.
- Check whether the unit is short of the refrigerant, add the refrigerant after leakage detection and repair welding.
- Check whether the sensor and electric control board is normal, otherwise replace the board.
Code: E5
Failure: Water level over limit
The reason of fault and solution:
- Normal, discharge the water out, it will return to normal condition automatically
- Check the water level switch, and replace it when fault.
Code: E8
Failure: Over heat protection
The reason of fault and solution:
- Check whether the fan is normal, otherwise replace corresponding motor or capacitance.
- Check the resistance of the electric heater is normal, otherwise replace it.
Dehumidifer Codes
Code: Continuous lamp flicker 2 times
Failure:Room temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of the sensor is normal, when it is abnormal the sensor should be replaced.
- Check whether there is short circuit or open circuit in the wire of the sensor, and whether the plug is connected well, whether there is welding off or rosin joint on the electric control board, if there is any, it should be repaired.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: Continuous lamp flicker 2/3 SEC
Failure: Coil temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of the sensor is normal, when it is abnormal the sensor should be replaced.
- Check whether there is short circuit or open circuit in the wire of the sensor, and whether the plug is connected well, whether there is welding off or rosin joint on the electric control board, if there is any, it should be repaired.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: Continuous lamp flicker 3 times
Failure: Humidity sensor fault
The reason of fault and solution:
- Check whether the humidity sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: Continuous lamp flicker 4 times
Failure: Temp. sensor and humidity sensor all fault
The reason of fault and solution:
- Check whether the resistance of the temperature sensor is normal, otherwise replace it.
- Check whether the humidity sensor is normal, otherwise replace it.
Code: Water full lamp flicker (light 0.5 SEC, extinguish 0.5 SEC)
Failure: Water full of water tank
The reason of fault and solution: Normal, discharge the water out, it will return to normal condition automatically
Inverter Split Codes
Code: F1
Failure: Communication fault
The reason of fault and solution:
- Check whether the connection of the outdoor unit and indoor unit is one to one, otherwise connect the L, N and communication line of the indoor unit and outdoor unit one to one.
- Measure whether the voltage between the zero line and the communication line is 18V-30AC half-wave signal, check whether the communication circuit on the indoor and outdoor electric control board has been damaged, otherwise replace it.
- Check whether the LED on the outdoor power board has been on, otherwise replace the electric control board.
- Check whether the unit is abnormal caused by the external interference, if it is, then find the interfering source, and removes it.
Code: F2
Failure: Ambient temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: F3
Failure: Coil pipe temp. sensor of indoor unit fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: F4
Failure: Fan motor of indoor
The reason of fault and solution:
- Check whether the contact of the plug of the motor wire and socket is well, making sure well contact
- Check whether the indoor motor has damaged, the motor should be replaced when it is damaged.
- Check whether the controllable silicon and other components on the electric control board have damaged, replace the controllable silicon or electric control board when they are damaged.
Code: F5
Failure: Module of outdoor unit fault
The reason of fault and solution:
- Check whether the connection of the compressor is reliable, otherwise connect firmly again.
- Check whether the fixation between the IPM module and the radiator is firm.
- Check whether the compressor is well, otherwise replace it.
- Check whether the IPM module is abnormal, otherwise replace it.
Code: F6
Failure: Ambient temp. sensor of outdoor fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: F7
Failure: Coil pipe temp. sensor of outdoor unit fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: F8
Failure: Suction temp. sensor of compressor fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: F9
Failure: Discharge temp. sensor of compressor fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: FA
Failure: Inductor of current or voltage fault
The reason of fault and solution: Check whether inductor of current or voltage have been damaged, they should be replaced if they are fault.
Code: FC
Failure: Compressor drive fault
The reason of fault and solution:
- Power on again, and check the operation of the compressor is normal.
- Check whether the connection of the compressor is reliable, otherwise repair.
- Check whether the components on the electric control board have been damaged, if they are damaged, the components or the electric control board should be replaced.
Code: FD
Failure: Phase lacking or phase sequence fault
The reason of fault and solution: Check power wire voltage or change two power wires.
Code: FE
Failure: Gas return sensor fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: FF
Failure: Other fault
Code: P1
Failure: Temp. of evaporator protection
The reason of fault and solution:
- Check whether the filter of indoor unit is too dirty, and it should be cleaned when it is too dirty.
- Check whether it has barrier around indoor unit, it should be remove if it has.
- Check whether the indoor motor is damaged, it should be replaced motor or electrical control board when it is damaged.
Code: P2
Failure: Overheat, over current protection of inverter module
The reason of fault and solution:
- Check whether the fixation between the IPM module and the radiator is firm.
- Check whether the compressor is well, otherwise replace it.
- Check whether the IPM module is abnormal, otherwise replace it.
Code: P3
Failure: Over current protection
The reason of fault and solution:
- Check whether the ambient temperature exceeds the operation range for the air conditioner
- Check whether the current detection circuit is abnormal, the electric control should be replaced when it is abnormal.
Code: P4
Failure: Discharge temp. of compressor protection
The reason of fault and solution:
- Check whether the air condition system and pressure are normal.
- Check whether the sensor, connecting wire of the sensor and the detection circuit are abnormal.
Code: P5
Failure: Over heat of compressor top protection
The reason of fault and solution:
- Check whether the air condition system and pressure are normal.
- Check whether the sensor, connecting wire of the sensor and the detection circuit are abnormal.
Code: P6
Failure: Suction temp. of compressor protection
The reason of fault and solution:
- Check whether the air condition system and pressure are normal.
- Check whether the sensor, connecting wire of the sensor and the detection circuit are abnormal.
Code: P7
Failure: Low or high voltage protection
The reason of fault and solution:
- Check whether the supply voltage is out of rang from 150 to 270V
- Check the voltage detection circuit of the IPM base board is abnormal, if it is abnormal, the IPM base board or the electric control board should be replaced.
Code: P8
Failure: Low presser of gas return protection
The reason of fault and solution: Check whether the pressure is normal when the unit is running, if it is abnormal, should detect the leakage and welding add refrigerant.
Code: P9
Failure: High pressure of discharge protection
The reason of fault and solution: Check whether the pressure is normal when the unit is running, if it is abnormal, should detect the leakage and welding add refrigerant.
Code: PA
Failure: High temp. of condenser protection
The reason of fault and solution:
- Check whether the condenser of outdoor unit is too dirty, and it should be cleaned when it is too dirty.
- Check whether it is running at bad condition long time.
- Check whether senor and wire are normal.
Code: PC
Failure: High temp. of outdoor ambient protection
The reason of fault and solution:
- Check the outdoor ambient temperature is too high or there is heat source around the outdoor unit.
- Check whether the sensor and sensor wire are normal.
Code: PF
Failure: Other protection
Multi-Split Series Codes
Code: F1
Failure: Communicate fault
The reason of fault and solution:
- Check whether the connection of the outdoor unit and indoor unit is one to one.
- Check whether the unit is abnormal caused by the external interference, if it is, then find the interfering source, and removes it.
- Check whether the electrical control board is damage, it should be replaced when it is damaged.
Code: F2
Failure: Indoor temp. sensor fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: F3
Failure: Outlet e temp. sensor of indoor unit coil pipe fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: F3
Failure: Suction temp. sensor of indoor unit coil pipe fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: F3
Failure: Middle temp. sensor of indoor unit coil pipe fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced
Code: F4
Failure: PG motor fault
The reason of fault and solution:
- Check whether the contact of the plug of the motor wire and socket is well, making sure well contact.
- Check whether the indoor motor has damaged, the motor should be replaced when it is damaged.
- Check whether the controllable silicon and other components on the electric control board have damaged, replace the controllable silicon or electric control board when they are damaged.
Code: P2
Failure: Protection of module fault
The reason of fault and solution:
- Check whether the connection of the compressor is reliable, otherwise connect firmly again.
- Check whether the fixation between the IPM module and the radiator is firm.
- Check whether the compressor is well, otherwise replace it.
- Check whether the IPM module is abnormal, otherwise replace it.
Code: P3
Failure: Over current of outdoor unit
The reason of fault and solution:
- Check whether the ambient temperature exceeds the operation range for the air conditioner
- Check whether the current detection circuit is abnormal, the electric control should be replaced when it is abnormal.
Code: P4
Failure: Discharge temp. of compressor too high, outside ambient temp. too high, temp. switch of compressor crust cut off, temp. of module too high.
The reason of fault and solution:
- Check whether the pressure is normal when the unit is running, if it is abnormal, should detect the leakage and welding add refrigerant.
- Check whether ambient temp. is too high or too low, when the temp. more than -20 degree and less 55 degree, it can disappear automatically.
- communicate interference, earth wire and communicate wire can’t put in one cable.
- Check whether temp. switch of compressor is damage, it should be replace if it damaged.
Code: P7
Failure: DC voltage abnormal of outdoor unit
The reason of fault and solution:
- Check whether the supply voltage is out of rang from 150 to 270V
- Check the voltage detection circuit of the IPM base board is abnormal, if it is abnormal, the IPM base board or the electric control board should be replaced.
Code: P8
Failure: Lack refrigerant or reverse valve fault
The reason of fault and solution:
- Check whether the high and low pressure valves have been opened, otherwise open the valves.
- Check whether the indoor coil pipe temperature sensor is normal, if it is abnormal, the sensor should be replaced.
- Check the system pressure is abnormal, if it is abnormal, should detect leakage repairing welding and adding the refrigerant.
Code: F6
Failure: Outside sensor fault
The reason of fault and solution:
- Check whether the resistance of sensor is normal, otherwise replace it.
- Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board, repair it if there is any above.
- When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced.
Code: FC
Failure: Outdoor unit drive fault, start compressor failure
The reason of fault and solution:
- Power on again, and check the operation of the compressor is normal.
- Check whether the connection of the compressor is reliable, otherwise repair.
- Check whether the components on the electric control board have been damaged, if they are damaged, the components or the electric control board should be replaced.
VRF System Error Codes
Eror Codes | Cause |
---|---|
FE | The first time to switch on and there is no address |
E0 | Errors of phase sequence or fault of losing phase |
E1 | Communication failure of indoor and outdoor unit |
E2 | T1 sensor fault |
E3 | T2 sensor fault |
E4 | T2B sensor fault |
E5 | Malfunction of outdoor unit |
E6 | Testing fault of zero-crossing signal |
E7 | EEPROM malfunction |
E8 | Wind testing fault of PG electric motor |
E9 | Communication fault of wire controller |
EE | Alarming fault of water level switch |
EF | Model conflict |
Manuals Pdf
- Newair Portable AC Error Codes and Troubleshooting - December 20, 2024
- Sharp AC Error Codes and Troubleshooting - December 15, 2024
- Marq By Flipkart AC Error Codes List With Fixes - December 15, 2024
Hello can i ask how to resolve the ff (other faults) ???
The description isnt really useful.
Any solutions for FF error code in chigo 12k split air conditioner ??
Hi
I have a Chico unit
It gives me a faulty code of FF means other fault
How should I resolve this
The room does not cool
Thanks in advance
On the 12000 btu model mini split I’m experiencing FF fault code. I know it suggests replacing the DC motot , (fan?) or PCB board. Is there a reset button/switch?
i went away for couple days and my chigo system has the temp 17 with 4 stars on top of temp it wont shuty of nothing its frozen there my remote shuts off but not system