Fujitsu Limited is a multinational Japanese information and communications technology company that was established in 1935. With headquarters in Tokyo, the company has made an impact on the Asia, and international markets. Currently the largest company by annual revenue in Japan, the company focuses on producing a wide range of home and commercial appliances. Ranging from air conditioning to date storage they have you covered.
Additionally, the company has a wide range of groups and its appliance company runs under the name Fujitsu General. The company manufactures air conditioners, and humidity control solutions, and has taken the world by storm. Opening offices in different areas of the world, they are now one of the largest air conditioner manufacturers and suppliers.
While Fujitsu is a leading corporation, but there are times when consumers face a troubling error code that they are unable to decipher. For such days, we are here to help you with a simple solution. Start by noting down the error code, and match it using the list below. Once you have the error code you can easily work your way to the fix. To help you out we have listed down some of the most common error codes for Fujitsu ACs.
Fujitsu Halcyon Mini Split Codes
Fujitsu AC Wired Remote Controller, When EE:EE is displayed on remote control , press “Energy Save” & “Zone Control” buttons simultaneously for longer than 3 secs. The error code will then be displayed on the LCD.
Error Codes | Meaning |
---|---|
E0:00 | Coms error - indoor to remote |
E1:00 | Coms error - indoor to outdoor |
E2:00 | Return air thermistor open circuit |
E3:00 | Return air thermistor short circuit |
E4:00 | Indoor coil thermistor open |
E5:00 | Indoor coil thermistor shorted |
E6:00 | Outdoor coil thermistor open |
E7:00 | Outdoor coil thermistor shorted |
EA:00 | Outdoor ambient thermistor open |
Eb:00 | Outdoor ambient thermistor shorted |
Ec:00 | Discharge pipe themistor open |
Ed:00 | Discharge pipe thermistor shorted |
EE:00 | High Pressure problem |
EF:00 | Discharge pipe temp. Problem - too high = short of gas |
OO | ID to RC Comms Fail |
O1 | ID to OD Comms Fail |
O2 | ID Air Sensor Open |
O3 | ID Air Sensor Close |
O4 | ID Pipe Sensor Open |
O5 | ID Pipe Sensor Close |
O6 | OD Pipe Sensor Fail |
O8 | Power Source Connection Failure |
O9 | Drain Problem Float switch operated |
OA | OD Air Sensor Fail |
OC | Discharge sensor Fail |
OE | Outdoor High Pressure Heatsink error |
11 | OD PCB Fail |
12 | ID Fan Fail |
13 | OD Signal Abnormal ID signal error |
14 | OD EEPROM Fail |
15 | Compressor Temp Failure |
16 | Pressure Switch Error |
17 | IPM Error |
18 | CT Error |
19 | Active Filter Module Error |
1A | Compressor Failure |
1B | OD Fan Failure |
1C | Inverter to PCB Comms Fail |
1D | 2 Way Valve sensor Fail |
1E | Expansion Valve Error |
1F | Connection ID Unit Error |
20 | Indoor manual switch abnormal |
24 | Excessive high pressure protection on cooling |
25 | PFC circuit error |
26 | Indoor signal error |
27 | Indoor signal error |
28 | Indoor heat exchanger temperature error |
29 | Outdoor heat exchanger temperature (middle) error |
2A | Power supply frequency detection error |
2B | Compressor temperature error |
2C | Four-way valve abnormal |
Press “Energy Save” & “Zone Control” buttons simultaneously for longer than 3 secs to return to normal operating mode.
Operation Flashing Lights
If you use a wired type remote controller, error codes will appear on the remote controller display. If you use a wireless remote controller, the lamp on the photo detector unit will output error codes by way of blinking patterns. See the lamp blinking patterns and error codes in the table below. An error display is displayed only during operation.
Red and Green Light | Current Models |
---|---|
Off-2 Flashes | Reverse Comms Fail at Startup |
Off-3 Flashes | Reverse Comms Fail In Use |
Off-4 Flashes | Forward Comms Fail at Startup |
Off-5 Flashes | Forward Comms Fail In Use |
Off-8 Flashes | Wired Remote Control Failure |
2 Flashes-2 Flashes | Indoor Air Sensor Fail |
2 Flashes-3 Flashes | Indoor Pipe Sensor Fail |
2 Flashes-4 Flashes | Indoor heat exchanger sensor error |
2 Flashes-6 Flashes | Float switch operated |
3 Flashes-2 Flashes | OD Disch Sensor Fail |
3 Flashes-3 Flashes | OD Pipe Sensor Fail |
3 Flashes-4 Flashes | OD Air Sensor Fail |
3 Flashes-7 Flashes | Heatsink Sensor Error |
3 Flashes-8 Flashes | Compressor Temp Sensor Fail |
4 Flashes-2 Flashes | Forced Auto Switch Welded |
4 Flashes-3 Flashes | Main Relay Welded |
4 Flashes-4 Flashes | Power Failure |
4 Flashes- 7 Flashes | VDD Permament Stop Protection |
4 Flashes-8 Flashes | Reverse VDD Permament Stop |
5 Flashes-2 Flashes | IPM Protection |
5 Flashes-3 Flashes | CT Abnormal |
5 Flashes-5 Flashes | Compressor Failure |
5 Flashes-6 Flashes | Outdoor Fan Failure |
6 Flashes-2 Flashes | ID Fan Motor Locked |
Flashes-3 Flashes | ID Fan Motor Rotation Error |
7 Flashes- 2 Flashes | High Discharge Temperature |
7 Flashes- 3 Flashes | High Pressure |
7 Flashes-4 Flashes | 4-Way valve abnormal |
7 Flashes- 5 Flashes | Pressure Switch Fail |
7 Flashes-6 Flashes | Compressor Temperature error |
8 Flashes- 2 Flashes | Active Filter AFM Fail 1st Time |
8 Flashes- 3 Flashes | Active Filter AFM Fail 2nd Time |
8 Flashes-4 Flashes | PFC Circuit Error |
Blinking-Blinking | PCB Failure |
Remote Controls Buttons Meaning
Manuals
Air Conditioner Installation Manual
AUXB04GALH Airstage VRF Service Manual
Halcyon Mini Splits Error Codes and Troubleshooting Guide
Inverter Duct Type Air Conditioner Manual
References
fujitsugeneral.com/us/support/faq/halcyon/troubleshooting.html
fujitsugeneral.com/us/resources/pdf/support/downloads/pdf-om-asug09-15lzas-01.pdf
- Samsung VRF (DVM) Error Codes List With Solutions - January 1, 2025
- Comfortstar AC Error Codes and Troubleshooting - January 1, 2025
- Newair Portable AC Error Codes and Troubleshooting - December 20, 2024
Hi this is Luis my codes on the Fujitsu Hacyon AOU18CL has 4 reds and 2 green . Forced automatic
SW welded. How can I fix it.Thank you.
Hello,
I have a CT error. (5 flash red and 3 flash green).
What is the CT the Current Trip or the Compressor Thermistor ?
Can you help me to solve this problem ?
with my asu12rls i have 5 blinking green lights and dayed intermitting double blinking orange light.
can you advise what is wrong?
thanks
I am getting a 7 blink Operation and a 6 blink Timer meanwhile the economy just flashes continuously.
Any help please.
It did just start getting cold here and the heat feature did work once before this happened.
Hello,
Indoor Fujitsu all three lights solid.
Indoor unit me 7 time operation and 2 times timer led blinking Ho rahi o general inverter ac he Kya Aap bata sakte Ho Kis chij ki error he Plzz help
Hi there I have an ac fujitsu which is showing fault code C00 / 15 what does it mean.
4 reds and 2 green . Forced automatic
SW welded. How can I fix it.Thank you.