Carrier Cassette AC Error Codes List and Solutions

Carrier Global Corporation is a US-based multinational home appliance company that started its journey back in 1915. The company started off strong as an independent manufacturer and distributor of ventilated air conditioning and heating systems offering a simple yet smart solution for homes and offices. While the business started from Palm Beach Gardens, Florida – it now has a reputable standing around the world. Making it one of the most reliable and promising air conditioning and heating companies in the world.

Offering its appliances in more than 160 countries Carrier is one of the handful of corporations that offer its appliances in six continents of the world. Along with that the company now offers a wide range of products that include but is not limited to residential and commercial appliances. Making them a one-stop solution for all your air conditioning and heating needs.

When facing an error code we suggest you grab a pen and paper to note down the code rather than pressing various buttons on your Carrier Cassette air conditioner. This way you will not risk damaging your appliance any further and will be able to find out the exact issue using the common error code list for Carrier Cassette air conditioners listed below. Once you nail down the issue you can easily call in a professional, or fix the issue yourself.

Cassette Fault Codes

Once a failure occurs with the indoor unit in operation, the green unit LED flashes at intervals of 0.5 seconds. The fault code is deduced from the number of times the green LED flashes, blocking unit operation. Between one flash cycle and the next one, a pause of 5 seconds elapses.

Error CodesDescription
2Condensate discharge pump
3Room air sensor fault
4Indoor unit coil sensor fault
6Filter dirty
7Outdoor unit failure
10EEPROM corrupt
11Card serial number damaged
12Address / zone incomplete
13Gas flow distributor corrupt
14Outdoor air thermistor
E0Collision model malfunction
E1In-outdoor unit communication checking channel is abnormal
E2Room temperature sensor checking channel is abnormal
E3Pipe temperature sensor (T2) checking channel is abnormall
E4Pipe temperature sensor (T2B) checking channel is abnorma
E5W ater pump temperature sensor
E6Outdoor malfunction
E7EEPROM malfunction
E8In door fan unit stall malfunction
E9Communication error between indoor unit and wired controller
F0Lifting panel communication checking channel is abnormal
F1Lifting panel malfunction
F2Lifting panel is not closed
F3Indoor master/slave unit communication checking channel is abnormal
F4Other malfunctions of master/ slave unit
EBDC motor speed out of control
ECRefrigerant leakage detection malfunction
EEWater-level alarm malfunction
EDOutdoor unit malfunction
DDHeating/Cooling mode conflict error
FPToo many indoor units in group control (maximum 16)
Carrier Cassette Air Conditioner Fault Codes
Carrier Cassette Air Conditioner Fault Codes

Troubleshooting

Carrier Cassette Display of Selected Functions
Carrier Cassette Display of Selected Functions

Aircon will not start:

  • The main switch is switched OFF, place the switch in the ON position.
  • The fuses on the main switch are burnt out; replace the fuses. ( this operation need to be carried out by qualified personnel only).
  • Wait for 3 minutes: protection against frequent compressor cycling is ON.
  • Selected temperature is higher than the room temperature (or lower in the heating mode).

The unit emits unpleasant smells:

Unpleasant smells can accumulate on the air filters and then be dispersed into the room during air conditioner operation. Switch the unit OFF and contact an authorised service centre to have the filters cleaned. Restart unit in the ventilation (fan only) mode and open windows to change room air.

The unit makes strange noises:

Occasionally the unit makes strange noises at start-up, during operation or when it has stopped. These are generally due to the effect of temperature changes on the plastic parts.

Air conditioner is not supplying enough cooling (or heating):

  • Air cannot circulate freely.
  • Dirty filter reduces air quantity circulating.
  • Filter must be cleaned by skilled personnel only.
  • Doors and/or windows are open.
  • Fan speed has been set to ‘low’.
  • Air flow direction is not correct for optimum ventilation.
  • Selected temperature is not correct.

P (Green LED) indicator is flashing:

System malfunction. Contact service organisation after having ensured that:

  • Air circulation is not obstructed.
  • Outdoor unit coil is not obstructed and causing severe reduction of air circulation.
  • Condensate drainage tube is not obstructed.

As regards fault codes to be communicated to the after-sales

Q (Red LED) indicator is illuminated:

In the heating mode, the LED switches on to indicate an active defrost condition.

Periodical checks

Carrier Cassette Periodical Checks
Carrier Cassette Periodical Checks

Remote Control Meaning

Carrier Cassette AC Remote Control Meaning
Carrier Cassette AC Remote Control Meaning

Cassette Led Flashing Meaning

Carrier Cassette Led Flashing Meaning
Carrier Cassette Led Flashing Meaning

Manual

Cassette Air Conditioner Manual

Carrier AC Error Codes

Danny Reese



*If you can't find the code you're looking for on our site, please let us know, and we'll update our database as soon as possible.

38 thoughts on “Carrier Cassette AC Error Codes List and Solutions”

  1. Hi! I have a 60,000BTU/hr Alliance Cassette split type air con unit. The air con wont start but only blinks the orange light on the display while showing error code E8. Once in a while, when I turn it off at the mains, the indoor fan attempts to run, but only very briefly and stops.

    The fault code list I googled only goes up to E6 and 7. Even these two last codes are said to not have been used and that if they show on the display, one must just replace the board.

    What could be the fault?

    Regards.

    Ronald (Blantyre, Malawi)

    Reply
  2. Hi. I installed a 48,000 btu aircon cassette inverter unit, model #..42tsv0481001231..it’s giving problems.. switches on n after a minute it switches off.. then on again then off… the cycle continues.. when it switches off then indoor n outdoor both switches off.. there’s no error.. is factory fault cos it’s still new.. pliz help

    Reply