Galanz is a Chinese manufacturer of home appliances and electronics. With headquarters in Foshan, Guangdong the company was founded back in 1978. Since its inception, the company has strived hard and made its way to the top. Just back in 2019, the company started manufacturing 50% of the world’s microwaves. Expanding its grasp to a whole new level pushes them out of Asia and sets them on the world’s map.
Over the years Galanz started producing air conditioners, toaster ovens, washing machines, refrigerators, and other home appliances. Currently, the company produces its appliances in Zhongshan City and the Shunde District of Foshan City. Employing over 50000 people in 13 subsidiaries alone.
When facing an error code we suggest you grab a pen and paper to note down the code rather than pressing various buttons on your Galanz ac. This way you will not risk damaging your appliance any further and will be able to find out the exact issue using the common error code list for Galanz AC error codes listed below. Once you nail down the issue you can easily call in a professional, or fix the issue yourself.
Codes List
When the outdoor coil pipe TEMP sensor is out of order or removed, the air conditioner will set to defrost automatically in order to prevent it not working normally while the outdoor coil pipe TEMP sensor is malfunction.
Indoor unit display and solve methods of protector stop ingredients in indoor unit and outdoor unit.
Error Codes | Solutions |
---|---|
F1 | Heat overloading protector |
F2 | Cool freeze protector |
F3 | Instantaneous power cut |
F4 | direct current fan motor no feedback |
F6 | PG motor faults |
F7 | Indoor TEMP sensor faults |
F8 | Indoor coil pipe TEMP sensor faults |
F9 | Outdoor coil pipe TEMP sensor faults |
1F | cool overloading protector |
2F | exhaust overheating protector |
3F | over or not enough pressure protector |
4F | over-current protector |
5F | IPM protector |
6F | defrost state |
7F | direct current compressor drive exceptional |
8F | direct current compressor cannt start |
E1 | The trouble of indoor unit room temperature sensor. |
E2 | The trouble of unit pipe temperature sensor. indoor |
E3 | The trouble of PG motor |
E5 | The trouble of bad communication of indoor unit and outdoor unit. |
E6 | The EEPRO of indoor unit error |
1E | The trouble of outdoor unit pipe temperature sensor |
3E | The trouble of exhaust sensor |
4E | The EEPRO of indoor unit error |
8E | The trouble of PFC |
Remote Control
Troubleshooting
The following cases are not troubles that will obstruct you in using please follow the fault analysis and continue using.
Operation | Explanation |
---|---|
Fan speed setting is not allowed in AUTO or DRY mode | The speed of the indoor fan is set to low in DRY mode. Fan speed of 3 steps is selected automatically in AUTO mode |
Compressor stops operation intermittently in DRY mode | Compressor operation is automatically controlled in DRY mode depending on the room temperature and humidity |
Compressor of the outdoor unit is operating although it is turned off in HEAT mode | When the unit is turned off while de-ice is activated, the compressor continues operation for up to 10 minutes (maximum) until the deice is completed |
Timer indicator lamp lights up and the air conditioner does not operate | Timer is being activated and the unit is in ready mode. The unit operates normally if the timer operation is cancelled |
The compressor and indoor fan stop intermittently in HEAT mode | The compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protect the compressor from overheated air in HEAT mode |
Indoor fan and outdoor fan stop intermittently in HEAT mode | The compressor operates in a reverse cycle to remove exterior ice in HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heat operation |
The compressor stops intermittently in COOL mode or DRY mode, and fan speed of the indoor unit decreases | The compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozen depending on the inside/outside air temperature |
Wiring Diagram
Manual
- Aux AC Error Codes – How To Fix Them - November 15, 2024
- LG VRF Error Codes List – Multi V - November 15, 2024
- Black and Decker AC Error Codes List and Fixes - November 1, 2024
I have ac galanz inverter 220v 12ooobtu indoour run fiw minut outdoor not started make code E5 on display please hlep me to solve code
buenas tardes en mi equipo galanz me aparece F1 como puedo solucionar este problema
Probable cuase for my 9k minisplit would go on after shutting it off by the remote.no error code is indicated.what reason please tell me
i have a galanz ac 2002 model AUS 18 HR 53 FA2 . When i try to start it starts ( comp starts , cond fan starts, indoor unit starts) and after few seconds it stops and alarm power and night mode flashes. any help on how to find problem?
what is EERPROM