Galanz AC Error Codes and Troubleshooting

Galanz is a Chinese manufacturer of home appliances and electronics. With headquarters in Foshan, Guangdong the company was founded back in 1978. Since its inception, the company has strived hard and made its way to the top. Just back in 2019, the company started manufacturing 50% of the world’s microwaves. Expanding its grasp to a whole new level pushes them out of Asia and sets them on the world’s map.

Over the years Galanz started producing air conditioners, toaster ovens, washing machines, refrigerators, and other home appliances. Currently, the company produces its appliances in Zhongshan City and the Shunde District of Foshan City. Employing over 50000 people in 13 subsidiaries alone.

When facing an error code we suggest you grab a pen and paper to note down the code rather than pressing various buttons on your Galanz ac. This way you will not risk damaging your appliance any further and will be able to find out the exact issue using the common error code list for Galanz AC error codes listed below. Once you nail down the issue you can easily call in a professional, or fix the issue yourself.

Codes List

When the outdoor coil pipe TEMP sensor is out of order or removed, the air conditioner will set to defrost automatically in order to prevent it not working normally while the outdoor coil pipe TEMP sensor  is malfunction.

Indoor unit display and solve methods of protector stop ingredients in indoor unit and outdoor unit.

Error CodesSolutions
F1Heat overloading protector
F2Cool freeze protector
F3Instantaneous power cut
F4direct current fan motor no feedback
F6PG motor faults
F7Indoor TEMP sensor faults
F8Indoor coil pipe TEMP sensor faults
F9Outdoor coil pipe TEMP sensor faults
1Fcool overloading protector
2Fexhaust overheating protector
3Fover or not enough pressure protector
4Fover-current protector
5FIPM protector
6Fdefrost state
7Fdirect current compressor drive exceptional
8Fdirect current compressor cannt start
E1The trouble of indoor unit room temperature sensor.
E2The trouble of unit pipe temperature sensor. indoor
E3The trouble of PG motor
E5The trouble of bad communication of indoor unit and outdoor unit.
E6The EEPRO of indoor unit error
1EThe trouble of outdoor unit pipe temperature sensor
3EThe trouble of exhaust sensor
4EThe EEPRO of indoor unit error
8EThe trouble of PFC

Remote Control

Galanz Air Conditioner Remote Control
Galanz Air Conditioner Remote Control
Galanz Air Conditioner Display Meaning
Galanz Air Conditioner Display Meaning

Troubleshooting

The following cases are not troubles that will obstruct you in using please follow the fault analysis and continue using.

OperationExplanation
Fan speed setting is not allowed in AUTO or DRY modeThe speed of the indoor fan is set to low in DRY mode. Fan speed of 3 steps is selected automatically in AUTO mode
Compressor stops operation intermittently in DRY modeCompressor operation is automatically controlled in DRY mode depending on the room temperature and humidity
Compressor of the outdoor unit is operating although it is turned off in HEAT modeWhen the unit is turned off while de-ice is activated, the compressor continues operation for up to 10 minutes (maximum) until the deice is completed
Timer indicator lamp lights up and the air conditioner does not operateTimer is being activated and the unit is in ready mode. The unit operates normally if the timer operation is cancelled
The compressor and indoor fan stop intermittently in HEAT modeThe compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protect the compressor from overheated air in HEAT mode
Indoor fan and outdoor fan stop intermittently in HEAT modeThe compressor operates in a reverse cycle to remove exterior ice in HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heat operation
The compressor stops intermittently in COOL mode or DRY mode, and fan speed of the indoor unit decreasesThe compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozen depending on the inside/outside air temperature

Wiring Diagram

Galanz AC Refrigerant Cycle Block Diagram
Galanz AC Refrigerant Cycle Block Diagram

 

Galanz Air Conditioner Wiring Diagram
Galanz Air Conditioner Wiring Diagram

Manual

Split Wall Mounted AC Manual

AUS-09C(H)53R130Dx Service Manual

Danny Reese
Latest posts by Danny Reese (see all)



*If you can't find the code you're looking for on our site, please let us know, and we'll update our database as soon as possible.

47 thoughts on “Galanz AC Error Codes and Troubleshooting”

  1. I have ac galanz inverter 220v 12ooobtu indoour run fiw minut outdoor not started make code E5 on display please hlep me to solve code

    Reply
  2. Probable cuase for my 9k minisplit would go on after shutting it off by the remote.no error code is indicated.what reason please tell me

    Reply
  3. i have a galanz ac 2002 model AUS 18 HR 53 FA2 . When i try to start it starts ( comp starts , cond fan starts, indoor unit starts) and after few seconds it stops and alarm power and night mode flashes. any help on how to find problem?