TCL Technology – Telephone Communication Limited is a Chinese electronics company that was founded in 1981. Based in Huizhou, Guangdong the company designs, develops, manufactures, and sells televisions, mobiles, washing machines, refrigerators, air conditioners, and other small appliances. Voted as the world’s 25th largest consumer electronics producer in 2010, the company has come a long way.
TCL air conditioner global was established in 1999 and has been offering the world specialized residential and commercial air conditioning units since then. The company has made a great impact on the world, offering everything from basic to top-of-the-line technology that can be found in many homes and commercial air conditioning units.
TCL is a widely recognized brand that has made its way to the top, becoming one of the best manufacturers and appliance distributors. That being said, there are times when customers have complained of facing technical issues regarding their air conditioning systems. To help you out we have listed down some of the most common error codes for TCL ACs. Start by noting down the error code, and match it using the list below. Once you have the error code you can easily work your way to the fix.
Protection and Fault Codes
E0: Indoor/outdoor communication fault
EC: Outdoor communication fault
E1: Room temperature sensor (IRT)
E2: Indoor pipe (coil) temperature sensor (IPT)
E3: Outdoor pipe (coil) temperature sensor (OPT)
E4: System abnormal
E5: Model configuration wrong
E6: Indoor fan motor fault
E7: Outdoor temperature sensor
E8: Exhaust temperature sensor
E9: Intelligent power module of drive and module fault
EF: Outdoor fan motor fault (DC Motor)
EA: Current sensor fault
EE: EEPROM fault
EP: Temperature switch fault (on top of the compressor)
EU: Voltage sensor fault
EH: Intake temperature sensor
P1: Overvoltage / undervoltage protection
P2: Overcurrent protection
P4: Exhaust overtemperature protection
P5: Subcooling protection under cooling mode
P6: Overheating protection under cooling mode
P7: Overheating protection under heating mode
P8: Outdoor overtemperature / under temperature protection
P9: Drive protection (software control)
P0: Module protection (hardware control)
Protection and Failure Display
- When protection display is available, controller will show error code, digital LED shows error code and setting temperature by turns.
- If there is more than one failure, it will show at first that in front of the error list.
- Protection display function can be selected in hardware, and the default don’t display;
- To insure of in and out communist is credibility, the failures relate to outdoor unit will remain failure state for 2 minutes max after recovered.
- In all failures, only sensor failures don’t have to repower to cancel.
Protection Display Codes List
Outdoor Failure Display
There is a LED on outdoor power board, when compressor is running; it is normally light; when no feedback of signal to power board from compressor, it will wink by lighting 1s and going out 1s. If failures happened, it will light 0.5s, go out 0.5s, winking several times and go out 3s for a cycle to indicate failures.
Wink time | Failure |
---|---|
1 | IPM protection |
2 | Higher or lower voltage |
3 | Over current |
4 | Discharge temperature too high |
5 | Outdoor coil temperature too high |
6 | Drive abnormity |
7 | Communication abnormity with indoor unit |
8 | Compressor over heat(switch on top of compressor) |
9 | Outdoor air temperature sensor failure |
10 | Outdoor coil temperature sensor failure |
11 | Outdoor discharge pipe temperature sensor failure |
12 | Voltage sensor failure |
13 | Current sensor failure |
14 | IPM abnormity |
15 | Outdoor communication abnormity |
16 | DC fan motor no feedback |
17 | Defrosting |
Portable AC Codes
This appliance has a self diagnosis system to identify a number of malfunctions. If an error message is displayed, please refer to the below table.
Error Codes | Problem |
---|---|
Lt | Low Temperature ( frost prevention). Action: The appliance is fitted with a frost protection device to avoid excessive formation of ice. The appliance starts up again automatically when the defrost process is completed. |
PF | Probe Failure ( sensor damaged). Action: If this is displayed, contact your local authorised service centre. |
Ft | Full tank ( safety tank full). Action: Empty the internal safety tank. |
AS | If the screen on the unit displays 'AS', the room temperature sensor has failed. Contact your Authorize Service Center. |
ES | If the screen on the unit displays 'ES', the pipe temperature sensor has failed. Contact your Authorize Service Center. |
P1 | If the screen on the unit displays 'P1', the water collection tank inside the unit should be full. If error repeats, contact your Authorize Service Center. |
Troubleshooting
Problem: Air conditioner will not start
Possible Causes:
- The air conditioner plug is not completely inserted into the electrical outlet.
- The fuse is blown or the circuit breaker has tripped.
- Power failure.
- P1 appears in the display.
- Room temperature is less than the set temperature.
Solutions:
- Make sure electrical plug is plugged completely into alive. properly grounded outlet.
- Replace the fuse or reset the circuit breaker. Make sure that there are no other appliances on the same circuit.
- If a power failure occurs, turn the power OFF. When power is restored, wait 3 minutes before restarting the air conditioner.
- The water collection tank is full. Drain the tank and reset your settings.
- This is normal. The air conditioner automatically shuts off when the room equals or is less than (Cool mode) or is more than (Heat mode)the set temperature. Adjust the temperature setting, if needed.
Problem: Air conditioner does not cool properly
Possible Causes:
- Airflow is restricted.
- The air filter is dirty.
- The room is very hot, or not enough time allowed for cooling.
- Cold air is escaping.
- Cooling coils have iced up.
Solutions:
- Make sure there is sufficient clearance around the air conditioner and that the air inlet and outlet are not blocked.
- Clean the air filter at least every two weeks.
- When first turned on, allow the air conditioner sufficient time to cool the room.
- Check for open furnace. floor registers cold air returns, open windows or doors.
- In especially cool, humid weather and when the air conditioner is running frequently or for extended periods, ice can form on the cooling coils, blocking air flow. It is normal, please adjust the temperature higher and High fan speed.
Problem: Air conditioner runs too often or too long
Possible Causes:
- Area to be cooled is too large for the air conditioner.
- Doors or windows are open.
Solutions:
- Consult your dealer for the air conditioner capacity necessary to cool the desired area.
- Make sure doors and windows are closed.
Cleaning The Filters
To keep your air air conditioner working efficiently, you should clean the filters every week of operation. Grasp the upper panel tab and take off the filter which behind the grill of the back panel as shown the right. Wash the filter using liquid dish washing detergent and warm water. Rinse filter thorough Gently shake excess water from the filter. Be sure filter is thoroughly dry before replacing. 0r, instead of washing you may vacuum the filter clean. Replace the filter after the filter is dry.
The ebinet and front may be dusted with an oiI-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dish washing detergent. Never use harsh cleaners, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner.
Wiring Diagram
Manual Pdf
Owner’s Manual Portable AC (Model TAC08-10)
Repair Guideline for TCL DC Inverter AC
Wall Mounted Split Type AC Service Manual
- Newair Portable AC Error Codes and Troubleshooting - December 20, 2024
- Sharp AC Error Codes and Troubleshooting - December 15, 2024
- Marq By Flipkart AC Error Codes List With Fixes - December 15, 2024
what does ER error mean
Hi, our aircon suddenly started showing the ‘E5’ code and stops working. When you turn it on (with the usual remote) it starts up and runs for a few minutes then shows ‘E5’ and stops. I see this means there is a ‘mismatch’ – but what does that mean and how can I fix it?
Hi, I had such a challenge with an LG cassette type and on the Error chart it means ‘mismatch’.Only to find that the drain pan was full because they left it on cooling mode for the whole night at this cold season. I Drained Out All That Water,and Reduced The Gas Pressure For Winter….And so far so good
Sometimes it can be the drain pump disfunctional
Hi , I have a P4 Error code on a 60 000btu TCL aircon. What is the problem and how do I fix it please?
Ours just started saying PO what do we need to do. Thank you.
i got a tcl unit model tcl 6o hrsa shows an error code el what wrong with the unit