The article explains the different error codes that may appear on Westpoint air conditioners and what they mean. It provides a comprehensive list of error codes and their possible causes, including sensor malfunctions, power issues, and refrigerant leaks.
Codes Table
Error Codes | Problem |
---|---|
C1 | Arc control |
C2 | Electrical leakage protection |
C5 | Jumper cap error |
EH | Auxiliary electrical heater error |
E0 | Water pump error |
E1 | High pressure protection of the compressor |
E2 | Anti-freezing protection of the indoor unit |
E3 | Low pressure protection of the compressor |
E4 | High discharge temperature protection of the compressor |
E5 | Overload protection of the compressor |
E6 | Communication error |
E8 | Indoor unit fan protection |
E9 | Water overflow protection |
F0 | Indoor ambient temperature sensor error at the return air inlet. |
F1 | Evaporator temperature sensor error |
F2 | Condenser temperature sensor error |
F3 | Indoor ambient temperature sensor error |
F4 | Discharge temperature sensor error |
F5 | Ambient temperature sensor error at the display |
FF | Sub-room switch opened |
Rooftop Codes
Error Codes | Problem |
---|---|
E0 | Compressor phase sequence error or phase default |
E1 | Outdoor coil sensor in sys. A error |
E2 | Outdoor coil sensor in sys. B error |
E3 | Overcurrent protection of system A are active 3 times within one hour. |
E4 | Overcurrent protection of systemB are active 3 times within one hour. |
E5 | Indoor coil sensor in sys. A error |
E6 | Indoor coil sensor in sys. B error |
E7 | High-Low pressure protection or discharge temperature protection of system A reached 3 times |
E8 | High-Low pressure protection or discharge temperature protection of system B reached 3 times |
E9 | Indoor sensor error |
EA | Outdoor ambient sensor error |
Eb | Wire controller output error |
P0 | Overcurrent protection in sys. A |
P1 | Overcurrent protection in sys. B |
P2 | Overcurrent protection for indoor fan |
P3 | Comprehensive protection for outdoor fan |
P4 | Protection for Hi/Lo pressure or exhause temp. in sys.A |
P5 | Protection for Hi/Lo pressure or exhauset temp. in sys.B |
P6 | Hi-pressure protection initiated in T2 evaporator stops the outdoor unit fan |
P7 | Hi-pressure protection initiated in T2 evaporator stops the outdoor unit fan and compressor |
P8 | Protection for condenser Hi-temp in sys A. |
P9 | Protection for condenser Hİ-temp in sys B. |
Pc | Anti-freezing protection for evaporator in sys. A |
Pd | Anti-freezing protection for evaporator in sys. B |
dF | Defrosting |
PA | Protection for outdoor temp |
Troubleshooting
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance.
Problem: Air conditioner does not start
Solution:
- Wall plug disconnected. Push plug firmly into wall outlet.
- House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
- Plug Current Device Tripped. Press the RESET button.
- Control is OFF. Turn Control ON and set to desired setting.
Problem: Air from unit does not feel cold enough.
Solution:
- Room temperature below 17 C(62 F). Cooling may not occur until room temperature rises above 17 C(62 F).
- Temperature sensing element touching cold coil, located behind air filter. Straighten tube away from coil.
- Reset to a Lower temperature.
- Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode.
Problem: Air conditioner cooling, but room is too warm- ice forming on cooling coil behind decorative front.
Solution:
- Outdoor temperature below 18 C(64 F). To defrost the coil, set FAN ONLY mode.
- Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY mode.
- Thermostat set too cold for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then, set temperature to a Higher setting.
Problem: Air conditioner cooling, but room is too warm- NO ice forming on cooling coil behind decorative front.
Solution:
- Dirty air filter- air restricted. Clean air filter. Refer to Care and Cleaning section.
- Temperature is set too High, set temperature to a Lower setting.
- Air directional louvers positioned improperly. Position louvers for better air distribution.
- Front of units is blocked by drapes, blinds, furniture, etc. – restricts air distribution. Clear blockage in front of unit.
- Doors, windows, registers, etc. Open- cold air escapes. Close doors, windows, registers.
- Unit recently turned on in hot room. Allow additional time to remove Stored heat from walls, ceiling, floor and furniture.
Problem: Air conditioner turns on and off rapidly
Solution:
- Dirty air filter- air restricted. Clean air filter.
- Outside temperature extremely hot. Set FAN speed to a Higher setting to bring air past cooling coils more frequently.
Problem: Noise when unit is cooling
Solution:
- Air movement sound. This is normal . If too loud, set to a slower FAN setting.
- Window vibration – poor installation. Refer to installation instructions or check with installer.
Problem: Water dripping INSIDE when unit is cooling
Solution: Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation instructions – check with installer.
Problem: Remote Sensing Deactivating Prematurely (some models)
Solution:
- Remote control not located within range. Place remote control within 20 feet & 180 , radius of the front of the unit.
- Remote control signal obstructed. Remove obstruction.
Remote Control
Manual
- Newair Portable AC Error Codes and Troubleshooting - December 20, 2024
- Sharp AC Error Codes and Troubleshooting - December 15, 2024
- Marq By Flipkart AC Error Codes List With Fixes - December 15, 2024
Westport floor stand comes with E04 how to solve
in Westpoint outdoor PCB
LED 01 Blinking
LED 02. Blinking
LED 03 Flash
What is the solution for this error?
Westpoint AC was on than it switch off and apear on the panel E06. what is that and how do I prevent it from happening again.
Aircon I switch off with remote control about a hour it’s on again I don’t know how
Sir! Westpoint fronstanding ac come in display =E01