Danby Portable AC Error Codes – Problems and Meaning

Danby Appliances Inc is a Montreal Quebec, Canadian-based company that was founded back in 1947. The company specializes in designing, manufacturing, and distributing appliances all over the local and international markets. Working with various retailers in Canada, the USA, Mexico, and the UK – they are able to offer the world what they have to offer.

Based in Guelph, Ontario and Findlay Ohio the company not only has a well-established name in Canada and other parts of the world. What was once a family-owned business, has now made its name as one of the best appliance businesses in the Americas. Generating more than 400 million dollars per year in sales alone, the company offers washing machines, air conditioners, microwaves, wine coolers, refrigerators, and other small appliances.

When facing an error code we suggest you grab a pen and paper to note down the code rather than pressing various buttons on your Danby portable AC. This way you will not risk damaging your appliance any further and will be able to find out the exact issue using the common error code list for Danby Portable AC Error codes listed below. Once you nail down the issue you can easily call in a professional, or fix the issue yourself.

Occasionally, a problem may arise that is minor in nature, and a service call may not be necessary. Use this troubleshooting guide for a possible solution.

Codes List

Error CodesProblem
E1Error with the coils temperature sensor.
E2Error with the indoor temperature sensor.
E4Frost protection: the temperature of the coil is too low and the A/C shuts down to prevent excess frost build-up. When the temperature increases to 8°C (46.4°F), the  protective setting is released and the previous setting is applied.
FtTank is full - Connect the drain hose and drain the collected water away. If error repeats, call for service.
P1Bottom tray is full - Connect the drain hose and drain the collected water away. If error repeats, call for service.
LtLow Temperature. The unit will defrost. The appliance will start again once defrosting is complete
PFProbe failure, call for service

Troubleshooting

Danby Portable Air Conditioner Troubleshooting
Danby Portable Air Conditioner Troubleshooting

Problem: Unit does not start when pressing on/off button

Possible Cause:

  1. P1 appears in the display window
  2. Room temperature is lower than the set temperature. (Cooling mode)

Solution:

  1. Drain the water in the bottom tray.
  2. Reset the temperature.

Problem: Not cool enough

Possible Cause:

  1. The windows or doors in the room are not closed.
  2. There are heat sources inside the room.
  3. Exhaust air duct is not connected or blocked.
  4. Temperature setting is too high.
  5. Air filter is blocked by dust.

Solution:

  1. Make sure all the windows and doors are closed.
  2. Remove the heat sources if possible.
  3. Connect the duct and make sure it can function properly.
  4. Decrease the set temperature.
  5. Clean the air filter.

Problem: Noisy or vibration

Possible Cause: The ground is not level or not flat enough.

Solution: Place the unit on a flat, level ground if possible.

Problem: Gurgling sound

Possible Cause: The sound comes from the flowing of the refrigerant inside the air conditioner

Solution: It is normal

Problem: Power shut off at Heating mode

Possible Cause: The automatic over heat protection function. When the temperature at the air outlet exceeds 70°C/158°F, the device wi ll stop.

Solution: Switch on again after the unit has cooled down.

Remote Control

Danby Portable AC Remote Control
Danby Portable AC Remote Control

Parts and Control Panel

Danby Portable Air Conditioner Parts
Danby Portable Air Conditioner Parts
Danby Portable Air Conditioner Control Panel
Danby Portable Air Conditioner Control Panel

Manual Pdf

Portable Air Conditioner Manual

Danny Reese
Latest posts by Danny Reese (see all)



*If you can't find the code you're looking for on our site, please let us know, and we'll update our database as soon as possible.

39 thoughts on “Danby Portable AC Error Codes – Problems and Meaning”

  1. My remote doesnt work all the time, I replaced batteries, I bought another remote to see if that was the problem. Now it doesnt even turn the unit on anymore. I think it may be the sensor on the unit not the remotes. Does anyone else have a problem with the remote? My remote has all the options and the base unit doesnt so I need this remote to work for the functions.

    Reply
  2. I have a
    Danby 14,000 BTU 3-in-1 Portable Air Conditioner with Silencer and Wireless Connect
    Out of the box I have an AP and EH03 error. What does this mean?

    Reply

Leave a Comment